Compared with the traditional networking with modular core switches, the entire network with RG-S6920-4C switches uses the Clos architecture, reducing the TCO by 25% and power consumption by 31%. Furthermore, RG-S6920-4C switches help build stable and lossless networks.
Models
Series
Highlight Features
Diverse ports, four service slots, up to 128 x 100GE QSFP28 ports or 64 x 100GE QSFP28 and 16 x 400GE QSFP-DD ports
Hardware-level redundancy, ensuring service continuity
Lossless Ethernet, ensuring zero packet loss during RDMA E2E communication
Telemetry-based network monitoring and automated O&M, making management simple and efficient
Highly-efficient heat dissipation and energy saving, with power consumption less than 1950 W and power conversion efficiency up to 94%
System Specifications |
RG-S6920-4C |
Ports |
100GE/400GE ports |
Expansion Module Slots |
Four expansion module slots, each supporting the line card with up to 32 × 100GE ports |
Expansion Modules |
Four power supply modules Six fan modules |
Management Port |
One management port, one console port, and one USB port, compliant with the USB2.0 standard |
Switching Capacity |
25.6 Tbps |
Packet Forwarding Rate |
8000 Mpps |
802.1Q VLAN |
4094 |
Dimensions and Weight |
RG-S6920-4C |
Dimensions |
442 mm x 735 mm x 173.6 mm (17.40 in. x 28.94 in. x 6.83 in., 4 RU) |
Weight |
About 34.25 kg (75.51 lbs., including all line cards, power supply modules, and fans) |
Power Supply and Consumption |
RG-S6920-4C |
Maximum Power Consumption |
● Max: 1950 W ● Typical: 1469 W ● Static: 516 W |
AC |
RG-PA1200I-F ● Rated voltage: 110 V AC/220 V AC ● Rated voltage range: 100 V AC to 240 V AC, 50 Hz to 60 Hz ● Max voltage range: 90 V AC to 264 V AC, 47 Hz to 63 Hz |
High-voltage DC |
Input voltage range: 180 VDC to 300 VDC |
Environment and Reliability |
RG-S6920-4C |
Operating Temperature |
0ºC to 40ºC (32ºF to 104ºF) |
Storage temperature |
-40 °C to +70 °C (-40 °F to +158 °F) |
Operating Humidity |
10% RH to 90% RH (Non-condensing) |
Storage humidity |
5% to 95% RH (non-condensing) |
Working altitude |
Operating altitude: up to 5000 m (16,404.20 ft.) Storage altitude: up to 5000 m (16,404.20 ft.) |
Software Specifications |
RG-S6920-4C |
L2 Protocols |
IEEE802.3ad (Link Aggregation Control Protocol), IEEE802.1p, IEEE802.1Q, IEEE802.1D (STP), IEEE802.1w (RSTP), IEEE802.1s (MSTP), IGMP Snooping, MLD Snooping, Jumbo Frame (9 KB), IEEE802.1ad (QinQ and selective QinQ), GVRP |
L3 Protocols (IPv4) |
BGP4, OSPFv2, RIPv1, RIPv2, MBGP, LPM Routing, Policy-based Routing (PBR), Route-policy, Equal-Cost Multi-Path Routing (ECMP), WCMP, VRRP, IGMP v1/v2/v3, DVMRP, PIM-SSM/SM/DM, MSDP, Any-RP |
IPv6 Basic Protocols |
Neighbor Discovery, ICMPv6, Path MTU Discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, ACLv6, TCP/UDP for IPv6, SNMP v6, Ping/Traceroute v6, IPv6 RADIUS, Telnet/SSH v6, FTP/TFTP v6, NTP v6, IPv6 MIB support for SNMP, VRRP for IPv6, IPv6 QoS |
IPv6 Features |
Static routing, ECMP, PBR, OSPFv3, RIPng, BGP4+, MLDv1/v2, PIM-SMv6, manual tunnel and IPv4 over IPv6 tunnel |
Data Center Features |
PFC, ECN, and other data center features M-LAG RDMA OpenFlow 1.3 |
Visualization |
gRPC sFLOW sampling INT |
ACL |
Standard IP-based ACL、Extended MAC-based ACL、Extended IP-bsaed ACL、Expert-level ACL、ACL 80、IPv6 ACL、Ingress/Egress ACLs、ACL Logging、ACL Counter (Ingress and egress counters are supported in interface or global configuration modes)、ACL Re-marking、Global ACL、ACL-based Redirection、Displaying ACL Resources、Processing First Packet of TCP Handshake When Binding the ACL to Restrict SIP、Matching Against 5-Tuple of Pass-by VXLAN Inner IP Packets、The expert-level ACL supports matching the IP flag and DSCP fields of VXLAN inner packets |
QoS |
Mapping of IEEE 802.1p, DSCP, and ToS priorities |
HA Design |
GR for RIP/OSPF/BGP, BFD, DLDP, REUP dual-link fast switching, RLDP unidirectional link detection, 1+1 power redundancy and fan redundancy, and hot swapping for all cards and power supply modules |
Security Features |
Network Foundation Protection Policy (NFPP), CPP, DDoS attack defense, illegitimate data packet detection, data encryption, source IP spoofing prevention, IP scanning prevention, RADIUS/TACACS, IPv4/v6 packet filtering by basic ACL, extended ACL or VLAN-based ACL, plaintext-based and MD5 ciphertext-based authentication for OSPF, RIPv2, and BGPv4 packets, telnet login and password mechanisms for restricted IP addresses, uRPF, broadcast packet suppression, DHCP Snooping, ARP spoofing prevention, ARP check, and hierarchical user management |
Management Mode |
SNMP v1/v2c/v3, telnet, console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP, Syslog, SPAN/RSPAN/ERSPAN, ZTP, NETCONF, Python, fan and power alarm function, temperature alarm function, and configuration rollback |
Other Protocols |
DHCP Client, DHCP Relay, DHCP Server, DNS Client, UDP relay, ARP Proxy, and Syslog |
Specification |
RG-S6920-4C |
Safety |
● IEC 62368-1 ● EN 62368-1 ● EN IEC 62368-1 ● BS EN IEC 62368-1 ● UL 62368-1 ● CSA C22.2#62368-1 ● GB 4943.1 |
Electromagnetic Compatibility (EMC) |
● EN 55032 ● EN 55035 ● EN IEC 61000-3-2 ● EN IEC 61000-3-3 ● EN 61000-3-3 ● ETSI EN 300 386 ● EN 300 386 ● ICES-003 Issue 7 ● ICES-003 Issue 6 ● ANSI C63.4-2014 ● FCC CFR Title 47, Part 15, Subpart B ● AS/NZS CISPR 32 ● CISPR 32 ● GB/T 9254.1 |
Environment |
● 2011/65/EU EN 50581 ● 2012/19/EU EN 50419 ● (EC) No.1907/2006 ● GB/T 26572 |
*For more country-specific regulatory information and approvals, contact your local sales agency.
The configuration procedure for the RG-S6920-4C switch is as follows:
Product Model |
Description |
RG-S6920-4C |
Four expansion slots, four power supply module slots, and six fan module slots |
RG-PA1200I-F |
Power supply module, supporting 2+2 redundancy, hot swapping, and front-to-rear ventilation design |
M2EFAN I-F |
Fan module, supporting 5+1 redundancy, hot swapping, and front-to-rear ventilation design |
Product Model |
Description |
M6900-32CQ |
32 x 100GE ports |
M6900-16CQ4QC |
16 × 100GE optical ports (QSFP28) + 4 × 400GE optical ports (QSFP-DD) |
Product Model |
Description |
400G-QDD-DR4-SM1310 |
400G DR4 module, QSFP-DD form factor, MPO-12 APC, 1310 nm, 500 m (1,640.42 ft.) over SMF |
400G-QDD-FR4-SM1310 |
400G FR4 module, QSFP-DD form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF |
400G-QDD-SR8-MM850 |
400G SR8 module, QSFP-DD form factor, MPO-16 APC, 850 nm, 100 m (328.08 ft.) over MMF |
Product Model |
Description |
100G-QSFP-SR-MM850 |
100G SR module, QSFP28 form factor, MPO, 850 nm, 100 m (328.08 ft.) over MMF |
100G-QSFP-iLR4-SM1310 |
100G iLR4 module, QSFP28 form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF |
100G-QSFP-LR4-SM1310 |
100G LR4 module, QSFP28 form factor, Duplex LC, 1310 nm, 10 km (32,808.40 ft.) over SMF |
100G-QSFP-ER4-SM1310 |
100G ER4 module, QSFP28 form factor, Duplex LC, 1310 nm, 40 km (131,233.59 ft.) over SMF |
100G-AOC-10M |
100G QSFP28 AOC cable, 10 m (32.81 ft.) |
100G-AOC-5M |
100G QSFP28 AOC cable, 5 m (16.40 ft.) |
Product Model |
Description |
40G-QSFP-iLR4-SM1310 |
40G iLR4 module, QSFP+ form factor, Duplex LC, 2 km (6,561.68 ft.) over SMF |
40G-QSFP-LR4-SM1310 |
40G LR4 module, QSFP+ form factor, Duplex LC, 10 km (32,808.40 ft.) over SMF |
40G-QSFP-LSR-MM850 |
40G LSR module, QSFP+ form factor, MPO, 400 m (1,312.34 ft.) over MMF |
40G-QSFP-SR-MM850 |
40G SR module, QSFP+ form factor, MPO, 150 m (492.13 ft.) over MMF |
40G-QSFP-LX4-SM1310 |
40G LX4 module, QSFP+ form factor, Duplex LC connector, 150 m (492.13 ft.) over OM3/OM4 MMF, or 2 km (6,561.68 ft.) over SMF |
40G-AOC-30M |
40G QSFP+ AOC cable, 30 m (98.43 ft.) |
40G-AOC-5M |
40G QSFP+ AOC cable, 5 m (16.40 ft.) |
Ruijie Networks websites use cookies to deliver and improve the website experience.
See our cookie policy for further details on how we use cookies and how to change your cookie settings.
Cookie Manager
When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.
Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.
This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.
Контакты
How can we help you?