RG-S7805C 4 RU Modular Campus Core Switch

Can be deployed in data centers, metropolis area networks, campus networks, or integrated scenarios of data centers and campus networks.

Models
Series
Highlight Features
  • Compact chassis design with a height of 4 RU, improving cabinet space utilization
  • Security defense policies, ensuring network robustness
  • VSU, delivering flexible networking capabilities and high performance
  • Hardware-level multi-protection, delivering carrier-grade reliability
  • SOE management software INC, enabling simplified and efficient O&M
Sales Enquiry
Key Specification View More
Функции

Modular Core Switch RG-S7805C

Compact chassis design with a height of 4 RU improves cabinet space utilization. A single card supports up to 52 non-combo ports and each card provides four fixed 10GE SFP+ ports. This enables the switch to achieve 10GE uplink connections and meet the networking requirements of small and medium-sized core networks or medium-sized network aggregation scenarios with a single card.

Security Defense Policies, Ensuring Network Robustness

CPP

NFPP

CPU Protection Policy (CPP) controls the types and traffic of packets sent to the CPU, preventing CPU usage exceptions.

VSU, Delivering Flexible Networking Capabilities and High Performance

VSU technology virtualizes multiple physical switches into one logical unit with a single IP address to realize unified management, simplifying O&M.
Fast link failover within 50 to 200 milliseconds ensures nonstop transmission of critical services.

Hardware-Level Multi-Protection, Delivering Carrier-Grade Reliability

Dual-Boot Redundancy
Dual-Boot Redundancy

Two flash chips for storing boot software achieve hardware-level boot redundancy, avoiding switch boot failures due to a flash chip fault.

1+1 Supervisor module Redundancy

1+1 hot standby ensures nonstop switch services.

Dual-Boot Redundancy
1+1 Supervisor module Redundancy
1+1 Power Supply Redundancy

Two hot-swappable power supplies realize failover within seconds and service continuity during power replacement, ensuring link reliability.

SOE Management Software INC Offers Easy and Efficient O&M

Automatic device registration and configuration after device connection, plug and play without commissioning, fast provisioning
Flexible replacement with no need form a bridge reconfiguration Auto-sensing on ports, facilitating automatic O&M
Intelligent identification and classification of terminals together with one-click access control and approvals Three-minute quick and auto onboarding
Zero-touch provisioning and plug and play Zero-touch provisioning and plug and play
Access control as well as quick onboarding Access control as well as quick onboarding
Zero-touch replacement and auto-sensing on ports Zero-touch replacement and auto-sensing on ports

Технические характеристики

Hardware Specifications (with -CM Series Supervisor Module)

Port specifications

RG-S7805C

RG-S7808C

RG-S7810C

Module slot

2 x supervisor module slots

3 x line card slots

2 x power module slots

1 x fan module slot

2 x supervisor module slots

6 x line card slots

4 x power module slots

2 x fan module slots

2 x supervisor module slots

8 x line card slots (slot 7 does not support the EB line card)

2 x switch fabric module slots

4 x power module slots

2 x fan module slots

Supervisor module

M7805C-CM II

M7808C-CM II

M7810C-CM

M7810C-CM-F

Switch fabric module

/

M7808C-CM II (switch fabric module integrated with supervisor module)

M7810C-FE-D I (must be used with M7810C-CM)

M7810C-FE-F I (must be used with M7810C-CM-F)

M7810C-CM, M7810C-CM-F (switch fabric module integrated with supervisor module)

line card

M7805C-CM II supports the following 9 modules:

● M7800C-32XS4QXS-DA

● M7800C-24GT24SFP4XS-EB

● M7800C-24SFP/12GT4XS-EB

● M7800C-48GT4XS-EB

● M7800C-48SFP4XS-EB

● M7800C-48GT-FA

● M7800C-48SFP-FA

● M7800C-48XS-FB

● M7800C-8CQ-FB

*1

M7808C-CM II supports the following 9 modules:

● M7800C-32XS4QXS-DA

● M7800C-24GT24SFP4XS-EB

● M7800C-24SFP/12GT4XS-EB

● M7800C-48GT4XS-EB

● M7800C-48SFP4XS-EB

● M7800C-48GT-FA

● M7800C-48SFP-FA

● M7800C-48XS-FB

● M7800C-8CQ-FB

*1

M7810C-CM supports the following 5 modules:

● M7800C-32XS4QXS-DA

● M7800C-24GT24SFP4XS-EB

● M7800C-24SFP/12GT4XS-EB

● M7800C-48GT4XS-EB

● M7800C-48SFP4XS-EB

M7810C-CM-F supports the following 4 modules:

● M7800C-48GT-FA

● M7800C-48SFP-FA

● M7800C-48XS-FB

● M7800C-8CQ-FB

*1

Power module

RG-PA300I-F

RG-PA460I-F

RG-PA1000I-F

RG-PA600I-F

RG-PA1600I-F

RG-PA600I

RG-PA1600I

Fan module

M05C-FAN (pre-installed 1)

M08-FAN (pre-installed 2)

M10C-FAN (pre-installed 2)

Module management port

M7805C-CM II:

● 1 x RJ45 console port

● 1 x RJ45 MGMT port

M7808C-CM II:

● 1 x RJ45 console port

● 1 x RJ45 MGMT port

M7810C-CM:

● 1 x RJ45 console port

● 1 x RJ45 MGMT port

M7810C-CM-F:

● 1 x RJ45 console port *2 

● 1 x mini USB console port *2

● 1 x RJ45 MGMT port

USB

M7805C-CM II: 1 x USB 2.0 port (no capacity limit, 2G/4G/8G/16G/32G capacity tested)

M7808C-CM II: 2 x USB 2.0 ports (no capacity limit, 2G/4G/8G/16G/32G capacity tested)

M7810C-CM: 1 x USB 2.0 port

M7810C-CM-F: 1 x USB 2.0 port

(no capacity limit, 2G/4G/8G/16G/32G capacity tested)

*1 Note: FA/FB series cannot be used with EB series or DA series.

*2 Note: Only one console port is allowed to be used at the same time. The mini USB console port has a higher priority.

System specifications

RG-S7805C

RG-S7808C

RG-S7810C

System packet forwarding rate *3

4500 Mpps

9000 Mpps

12000 Mpps

System switching capacity *4

6000 Gbps

12000 Gbps

16000 Gbps

CPU

Supervisor module:

● M7805C-CM II: quad-core CPU, each core with the clock speed of 1.0 GHz

Line card

● EB card: quad-core CPU, each core with the clock speed of 1.0 GHz

● DA/FA/FB card: quad-core CPU, each core with the clock speed of 1.5 GHz

Supervisor module:

● M7808C-CM II: quad-core CPU, each core with the clock speed of 1.5 GHz

Line card

● EB card: quad-core CPU, each core with the clock speed of 1.0 GHz

● DA/FA/FB card: quad-core CPU, each core with the clock speed of 1.5 GHz

Supervisor module:

● M7810C-CM, M7810C-CM-F: quad-core CPU, each core with the clock speed of 1.5 GHz

Line card

● EB card: quad-core CPU, each core with the clock speed of 1.0 GHz

● DA/FA/FB card: quad-core CPU, each core with the clock speed of 1.5 GHz

Switch fabric module

● M7810C-FE-D I, M7810C-FE-F I: quad-core CPU, each core with the clock speed of 1.5 GHz

Real-time clock (RTC)

M7805C-CM II: supported

M7808C-CM II: supported

M7810C-CM/M7810C-CM-F: supported

BootROM

M7805C-CM II:8 MB

EB card: 8 MB

DA/FA/FB card: 16 MB

M7808C-CM II: 16 MB

EB card: 8 MB

DA/FA/FB card: 16 MB

M7810C-CM/M7810C-CM-F: 16 MB

EB card: 8 MB

DA/FA/FB card: 16 MB

M7810C-FE-D I/M7810C-FE-F I: 16 MB

Flash memory

M7805C-CM II: 1 GB

EB card: 512 MB

DA/FA/FB card: 8 GB

M7808C-CM II: 8 GB

EB card: 512 MB

DA/FA/FB card: 8 GB

M7810C-CM/M7810C-CM-F: 8 GB

EB card: 512 MB

DA/FA/FB card: 8 GB

M7810C-FE-D I/M7810C-FE-F I: 8 GB

Memory

M7805C-CM II: 4 GB DDR3

EB card: 1 GB DDR3

DA card: 1 GB DDR4

FA/FB card: 2 GB DDR4

M7808C-CM II: 4 GB DDR4

EB card: 1 GB DDR3

DA card: 1 GB DDR4

FA/FB card: 2 GB DDR4

M7810C-CM/M7810C-CM-F: 4 GB DDR4

EB card: 1 GB DDR3

DA card: 1 GB DDR4

FA/FB card: 2 GB DDR4

M7810C-FE-D I: 1 GB DDR4

M7810C-FE-F I: 2 GB DDR4

Switch buffer

EB: 4 MB

FB: 32 MB

FA: 8 MB

DA: 16 MB

EB: 4 MB

FB: 32 MB

FA: 8 MB

DA: 16 MB

EB: 4 MB

FB: 32 MB

FA: 8 MB

DA: 16 MB

*3 means the system's packet forwarding rate.

*4 means the system's switching capacity.

Power supply and consumption

RG-S7805C

RG-S7808C

RG-S7810C

Power supply

2 x pluggable power modules

4 x pluggable power modules

4 x pluggable power modules

Power input

RG-PA300I-F (AC input):

● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz

● Maximum input voltage: 90 V AC to 264 V AC; 47 Hz to 63 Hz

● Maximum input current: 5 A

RG-PA460I-F (AC input):

● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz

● Maximum input voltage: 90 V AC to 290 V AC; 45 Hz to 63 Hz

● Maximum input current: 6 A

RG-PA1000I-F (AC input):

● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz

● Maximum input voltage: 90 V AC to 264 V AC; 47 Hz to 63 Hz

● Maximum input current: 10 A

RG-PA600I-F (AC input):

● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz

● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz

● Maximum input current: 10 A

RG-PA1600I-F (AC input):

● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz

● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz

● Maximum input current: 16 A

RG-PA600I (AC input):

● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz

● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz

● Maximum input current: 8 A

RG-PA1600I (AC input):

● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz

● Maximum input voltage: 90 V AC to 264 V AC; 47 Hz to 63 Hz

● Maximum input current: 16 A

Maximum output power

RG-PA300I-F: 300 W

RG-PA460I-F: 460 W

RG-PA1000I-F:

● 100 V AC to 176 V AC: 800 W

● 176 V AC to 240 V AC: 1000 W

RG-PA600I-F: 600 W

RG-PA1600I-F:

● 100 V AC to 176 V AC: 1200 W

● 176 V AC to 240 V AC: 1600 W

RG-PA600I: 600 W

RG-PA1600I:

● 100 V AC to 176 V AC: 1200 W

● 176 V AC to 240 V AC: 1600 W

Module power consumption

M05C-FAN: < 80 W

M7805C-CM II: < 21 W

M08-FAN: < 88 W

M7808C-CM II: < 50 W

M10C-FAN: < 216 W

M7810C-CM: < 50 W

M7810C-CM-F: < 110 W

M7800C-32XS4QXS-DA: < 210 W

M7800C-24GT24SFP4XS-EB: < 88 W

M7800C-24SFP/12GT4XS-EB: < 85 W

M7800C-48GT4XS-EB: < 70 W

M7800C-48SFP4XS-EB: < 101 W

M7800C-48GT-FA: < 75 W

M7800C-48SFP-FA: < 95 W

M7800C-48XS-FB: < 160 W

M7800C-8CQ-FB: < 130 W

 

Dimensions and Weight

RG-S7805C

RG-S7808C

RG-S7810C

Unit dimensions (W x D x H)

442 mm x 451 mm x 175 mm (17.40 in. x 17.76 in. x 6.89 in.)

442.0 mm x 465.0 mm x 441.7 mm (17.40 in. x 18.31 in. x 17.39 in.)

442.5 mm x 560.0 mm x 442.0 mm (17.42 in. x 22.05 in. x 17.40 in.)

Shipping dimensions (W x D x H)

750.0 mm x 600.0 mm x 455.0 mm (29.53 in. x 23.62 in. x 17.91 in.)

710.0 mm x 590.0 mm x 735.0 mm (27.95 in. x 23.23 in. x 28.94 in.)

845.0 mm x 685.0 mm x 770.0 mm (33.27 in. x 26.97 in. x 30.31 in.)

Rack height

4 RU

10 RU

10 RU

Unit weight

12.42 kg (27.38 lbs, empty chassis with 1 fan module)

35.60 kg (78.48 lbs, empty chassis with 2 fan modules)

43.60 kg (96.01 lbs, empty chassis with 2 fan modules)

Shipping weight

28.05 kg (61.84 lbs)

43.93 kg (96.85 lbs)

68.30 kg (150.58 lbs)

 

Environment and reliability

RG-S7805C

RG-S7808C

RG-S7810C

Temperature

Operating temperature: 0°C to 50°C (32°F to 122°F)

Storage temperature: –40°C to +70°C (–40°F to +158°F)

Humidity

Operating humidity: 10% to 90% RH (non-condensing)

Storage humidity: 5% to 95% RH (non-condensing)

Altitude

Operating altitude: –500 m to +5,000 m (–1,640.42 ft. to +16,404.20 ft.)

Storage altitude: –500 m to +5,000 m (–1,640.42 ft. to +16,404.20 ft.)

Mean time between failure (MTBF)

216,000 hours (about 24 years)

216,000 hours (about 24 years)

342,000 hours (about 39 years)

Fan

1 x pluggable fan module (pre-installed)

2 x pluggable fan modules (pre-installed)

2 x pluggable fan modules (pre-installed)

Heat dissipation

Supervisor module: right-to-left airflow

Line card: right-to-rear airflow

Power module: built-in fan modules drawing air outward, front-to-rear airflow

Supervisor module: right-to-rear airflow

Line card: right-to-rear airflow

Power module: front-to-rear airflow

Supervisor module: front-to-rear airflow

Line card: side-to-rear airflow

FE card: front-to-rear airflow

Acoustic noise

27°C (80.6°F): 70 dB

Max Noise: 77 dB

27°C (80.6°F): 70 dB

Max Noise: 77 dB

27°C (80.6°F): 70 dB

Max Noise: 77 dB

Supervisor module redundancy

1+1 redundancy

1+1 redundancy

1+1 redundancy (same model)

Power module redundancy

1+1 redundancy (same model)

N+M redundancy (same model)

N+M redundancy (same model)

Fan redundancy

Not supported

1+1 redundancy

1+1 redundancy

Module hot swapping

Supported

Supported

Supported

Power module hot swapping

Supported

Supported

Supported

Fan module hot swapping

Supported

Supported

Supported

Cable hot swapping

All ports on line cards support hot swapping of cables.

The switch-mode power supply supports hot swapping of power cords.

Power supply monitoring

Monitoring of the model, temperature, power, and voltage of the power supply module

Power supply failure alarming

Control of line card power-on based on the power supply status

Fan monitoring

Fan speed adjustment: 256 levels

Fan failure alarming

Temperature monitoring

Over-temperature alarming

ESD

ESD contact/air discharge: 6 kV/8 kV

ESD susceptibility contact/air discharge: 8 kV/15 kV

Surge protection

MGMT port: 4 kV

Service port: 4 kV

Power port: 6 kV

 

Certifications and regulatory compliance

RG-S7805C

RG-S7808C

RG-S7810C

Safety regulation

IEC 62368-1

EMC regulation

EN 300386, EN 55032 Class A, EN 55035,

EN IEC 61000-3-2, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3,

EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11

RoHS

European RoHS Directive 2011/65/EU & Amendment(EU) 2015/863

 

Hardware Specifications (with -X Series Supervisor Module)

Port specifications

RG-S7805C

RG-S7808C

RG-S7810C-X

Module slot

2 x supervisor module slots

3 x line card slots

2 x power module slots

1 x fan module slot

2 x supervisor module slots

6 x line card slots

4 x power module slots

2 x fan module slots

2 x supervisor module slots

8 x line card slots

4 x switch fabric module slots

4 x power module slots

2 x fan module slots

Supervisor module

M7805C-CM-X

M7808C-CM-X

M7810C-CM-X

Switch fabric module

/

M7808C-CM-X (switch fabric module integrated with supervisor module)

M7810C-FE-X I

M7810C-FE-X II

line card

M7800C-48GT4XS-XA

M7800C-48SFP4XS-XA

M7800C-24GT8SFP8XS-XA

M7800C-32XS-XA

M7800C-52XS-XB

M7800C-12CQ-XB

M7800C-48XT-P-XB

M7800C-48GT4XS-XA

M7800C-48SFP4XS-XA

M7800C-24GT8SFP8XS-XA

M7800C-32XS-XA

M7800C-52XS-XB

M7800C-12CQ-XB

M7800C-48XT-P-XB

M7800C-8SFG-XB

M7800C-8SFX-XB

M7800C-48GT4XS-XA

M7800C-48SFP4XS-XA

M7800C-24GT8SFP8XS-XA

M7800C-32XS-XA

M7800C-52XS-XB

M7800C-12CQ-XB

M7800C-48XT-P-XB

M7800C-8SFG-XB

M7800C-8SFX-XB

Power module

RG-PA300I-F

RG-PA460I-F

RG-PA1000I-F

RG-PA600I-F

RG-PA1600I-F

RG-PA600I

RG-PA1600I

RG-PD600I

Fan module

M05C-FAN (pre-installed 1)

M08-FAN (pre-installed 2)

M10C-FAN (pre-installed 2)

Module management port

M7805C-CM-X:

● 1 x RJ45 console port

● 1 x RJ45 MGMT port

M7808C-CM-X:

● 1 x RJ45 console port

● 1 x RJ45 MGMT port

M7810C-CM-X:

● 1 x RJ45 console port

● 1 x RJ45 MGMT port

M7810C-FE-X I/II:

● 1 x RJ45 console port

USB

M7805C-CM-X: 1 x USB 2.0 port (no capacity limit, 2G/4G/8G/16G/32G capacity tested)

M7808C-CM-X: 1 x USB 2.0 port (no capacity limit, 2G/4G/8G/16G/32G capacity tested)

M7810C-CM-X: 1 x USB 2.0 port (no capacity limit, 2G/4G/8G/16G/32G capacity tested)

 

System specifications

RG-S7805C

RG-S7808C

RG-S7810C-X

System packet forwarding rate *3

4500 Mpps

9000 Mpps

14300 Mpps

System switching capacity *4

6000 Gbps

12000 Gbps

19200 Gbps

CPU

Supervisor module:

● M7805C-CM-X: quad-core processor, each core 2.2 GHz

Line card:

● XA/XB series line card: quad-core processor, each core 2.2 GHz

Supervisor module:

● M7808C-CM-X: quad-core processor, each core 2.2 GHz

Line card:

● XA/XB series line card: quad-core processor, each core 2.2 GHz

Supervisor module:

● M7810C-CM-X: quad-core processor, each core 2.2 GHz

Line card:

● XA/XB series line card: quad-core processor, each core 2.2 GHz

Real-time clock (RTC)

M7805C-CM-X: supported

M7808C-CM-X: supported

M7810C-CM-X: supported

BootROM

M7805C-CM-X: 16 MB

XA/XB card: 16 MB

M7808C-CM-X: 16 MB

XA/XB card: 16 MB

M7810C-CM-X: 16 MB

M7810C-FE-X I/II: 16 MB

XA/XB card: 16 MB

Flash memory

M7805C-CM-X: 8 GB

XA/XB card: 8 GB

M7808C-CM-X: 8 GB

XA/XB card: 8 GB

M7810C-CM-X: 8 GB

M7810C-FE-X I/II: 8 GB

XA/XB card: 8 GB

Memory

M7805C-CM-X: 4 GB DDR4

XA/XB card: 4 GB DDR4

M7808C-CM-X: 4 GB DDR4

XA/XB card: 4 GB DDR4

M7810C-CM-X: 4 GB DDR4

M7810C-FE-X I: 1 GB DDR4

M7810C-FE-X II: 4 GB DDR4

XA/XB card: 4 GB DDR4

Switch buffer

XA series line card (excluding M7800C-32XS-XA): 4 MB

XB series line card: 35 MB

M7800C-32XS-XA: 35 MB

XA series line card (excluding M7800C-32XS-XA): 4 MB

XB series line card: 35 MB

M7800C-32XS-XA: 35 MB

XA series line card (excluding M7800C-32XS-XA): 4 MB

XB series line card: 35 MB

M7800C-32XS-XA: 35 MB

*3 means the system's packet forwarding rate.

*4 means the system's switching capacity.

 

Power supply and consumption

RG-S7805C

RG-S7808C

RG-S7810C-X

Power supply

2 x pluggable power modules

4 x pluggable power modules

4 x pluggable power modules

Power input

RG-PA300I-F (AC input):

● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz

● Maximum input voltage: 90 V AC to 264 V AC; 47 Hz to 63 Hz

● Maximum input current: 5 A

RG-PA460I-F (AC input):

● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz

● Maximum input voltage: 90 V AC to 290 V AC; 45 Hz to 63 Hz

● Maximum input current: 6 A

RG-PA1000I-F (AC input):

● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz

● Maximum input voltage: 90 V AC to 264 V AC; 47 Hz to 63 Hz

● Maximum input current: 10 A

RG-PA600I-F (AC input):

● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz

● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz

● Maximum input current: 10 A

RG-PA1600I-F (AC input):

● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz

● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz

● Maximum input current: 16 A

RG-PA600I (AC input):

● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz

● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz

● Maximum input current: 8 A

RG-PA1600I (AC input):

● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz

● Maximum input voltage: 90 V AC to 264 V AC; 47 Hz to 63 Hz

● Maximum input current: 16 A

RG-PD600I (DC input):

● Rated input voltage: –48 V DC

● Maximum input voltage: –40 V DC to –75 V DC

● Maximum input current: 20 A

Maximum output power

RG-PA300I-F: 300 W

RG-PA460I-F: 460 W

RG-PA1000I-F:

● 100 V AC to 176 V AC: 800 W

● 176 V AC to 240 V AC: 1000 W

RG-PA600I-F: 600 W

RG-PA1600I-F:

● 100 V AC to 176 V AC: 1200 W

● 176 V AC to 240 V AC: 1600 W

RG-PA600I: 600 W

RG-PA1600I:

● 100 V AC to 176 V AC: 1200 W

● 176 V AC to 240 V AC: 1600 W

RG-PD600I: 600 W

Module power consumption

M05C-FAN: < 80 W

M7805C-CM-X: < 40 W

M08-FAN: < 88 W

M7808C-CM-X: < 62 W

 

 

M7800C-8SFG-XB: < 250 W

M7800C-8SFX-XB: < 250 W

M10C-FAN: < 216 W

M7810C-CM-X: < 60 W

M7810C-FE-X I: < 50 W

M7810C-FE-X II: < 160 W

M7800C-8SFG-XB: < 250 W

M7800C-8SFX-XB: < 250 W

M7800C-48GT4XS-XA: < 85 W

M7800C-48SFP4XS-XA: < 117 W

M7800C-24GT8SFP8XS-XA: < 95 W

M7800C-32XS-XA: < 149 W

M7800C-52XS-XB: < 250 W

M7800C-12CQ-XB: < 240 W

M7800C-48XT-P-XB: < 300 W


If the PoE function is used, you need to separately configure the PoE power chassis M78-PSE-X and the power module RG-PA1600I-PL for M7800C-48XT-P-XB.

Hardware Specifications

M78-PSE-X

Fixed service port

2 x PoE out ports

Module slot

2 x power module slots

Power module

RG-PA1600I-PL

Power supply

2 x pluggable power modules

Power input

RG-PA1600I-PL (AC input):

● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz

● Maximum input voltage: 90 V AC to 264 V AC; 47 Hz to 63 Hz

● Maximum input current: 16 A

Maximum output power

RG-PA1600I-PL

● 100 V AC to 176 V AC: 1200 W

● 176 V AC to 240 V AC: 1600 W

PoE output power

Each PoE out port provides up to 1,440 W of power

Unit dimensions (W x D x H)

400.0 mm x 420.0 mm x 44.7 mm (15.75 in. x 16.54 in. x 1.76 in.)

Unit weight

5.0 kg (11.02 lbs)

Temperature

Operating temperature: 0°C to 50°C (32°F to 122°F)
Storage temperature: –40°C to +70°C (–40°F to +158°F)

Humidity

Operating humidity: 10% to 90% RH (non-condensing)
Storage humidity: 5% to 95% RH (non-condensing)

Mean time between failure (MTBF)

4,289,000 hours (about 489 years)

Power module redundancy

1+1 redundancy (same model)

 

Dimensions and Weight

RG-S7805C

RG-S7808C

RG-S7810C-X

Unit dimensions (W x D x H)

442 mm x 451 mm x 175 mm (17.40 in. x 17.76 in. x 6.89 in.)

442.0 mm x 465.0 mm x 441.7 mm (17.40 in. x 18.31 in. x 17.39 in.)

442.5 mm x 560.0 mm x 442.0 mm (17.42 in. x 22.05 in. x 17.40 in.)

Shipping dimensions (W x D x H)

750.0 mm x 600.0 mm x 455.0 mm (29.53 in. x 23.62 in. x 17.91 in.)

710.0 mm x 590.0 mm x 735.0 mm (27.95 in. x 23.23 in. x 28.94 in.)

845.0 mm x 685.0 mm x 770.0 mm (33.27 in. x 26.97 in. x 30.31 in.)

Rack height

4 RU

10 RU

10 RU

Unit weight

12.42 kg (27.38 lbs, empty chassis with 1 fan module)

35.6 kg (78.48 lbs, empty chassis with 2 fan modules)

43.55 kg (96.01 lbs, empty chassis with 2 fan modules)

Shipping weight

28.05 kg (61.84 lbs)

43.93 kg (96.85 lbs)

68.30 kg (150.58 lbs)

 

Environment and reliability

RG-S7805C

RG-S7808C

RG-S7810C-X

Temperature

Operating temperature: 0°C to 50°C (32°F to 122°F)

Storage temperature: –40°C to +70°C (–40°F to +158°F)

Humidity

Operating humidity: 10% to 90% RH (non-condensing)

Storage humidity: 5% to 95% RH (non-condensing)

Altitude

Operating altitude: –500 m to +5,000 m (–1,640.42 ft. to +16,404.20 ft.)

Storage altitude: –500 m to +5,000 m (–1,640.42 ft. to +16,404.20 ft.)

Mean time between failure (MTBF)

216,000 hours (about 24 years)

216,000 hours (about 24 years)

342,000 hours (about 39 years)

Fan

1 x pluggable fan module (pre-installed)

2 x pluggable fan modules (pre-installed)

2 x pluggable fan modules (pre-installed)

Heat dissipation

Supervisor module: right-to-left airflow

Line card: right-to-rear airflow

Power module: built-in fan modules drawing air outward, front-to-rear airflow

Supervisor module: right-to-rear airflow

Line card: right-to-rear airflow

Power module: front-to-rear airflow

Supervisor module: front-to-rear airflow

Line card: side-to-rear airflow

FE card: front-to-rear airflow

Acoustic noise

27°C (80.6°F): 70 dB

Max Noise: 77 dB

27°C (80.6°F): 70 dB

Max Noise: 77 dB

27°C (80.6°F): 70 dB

Max Noise: 77 dB

Supervisor module redundancy

1+1 redundancy

1+1 redundancy

1+1 redundancy

Power module redundancy

1+1 redundancy (same model)

N+M redundancy (same model)

N+M redundancy (same model)

Fan redundancy

Not supported

1+1 redundancy

1+1 redundancy

Module hot swapping

Supported

Supported

Supported

Power module hot swapping

Supported

Supported

Supported

Fan module hot swapping

Supported

Supported

Supported

Cable hot swapping

All ports on line cards support hot swapping of cables.

The switch-mode power supply supports hot swapping of power cords.

Power supply monitoring

Monitoring of the model, temperature, power, and voltage of the power supply module

Power supply failure alarming

Control of line card power-on based on the power status

Fan monitoring

Fan speed adjustment: 256 levels

Fan failure alarming

Temperature monitoring

Over-temperature warning

ESD

ESD contact/air discharge: 6 kV/8 kV

ESD susceptibility contact/air discharge: 8 kV/15 kV

Surge protection

MGMT port: 4 kV

Service port: 4 kV

Power port: 6 kV

 

Certifications and regulatory compliance

RG-S7805C

RG-S7808C

RG-S7810C-X

Safety regulation

IEC 62368-1

EMC regulation

EN 300386, EN 55032 Class A, EN 55035,

EN IEC 61000-3-2, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3,

EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11

RoHS

European RoHS Directive 2011/65/EU & Amendment(EU) 2015/863

 

Software Specifications (with -CM Series Supervisor Module)

Feature

RG-S7800C Series

Ethernet switching

Jumbo frame (maximum length: 9,216 bytes)

802.3az EEE

Maximum number of VLANs that can be created: 4,094

Voice VLAN

Super-VLAN and private VLAN

MAC address-based, port-based, protocol-based, and IP subnet-based VLAN assignment

GVRP

Basic QinQ and selective QinQ

STP (IEEE 802.1.d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s)

ERPS (G.8032)

LLDP/LLDP-MED

IP service

Static and dynamic ARP

DHCP client

DHCP relay

DHCP server

DHCP snooping

DNS

DHCPv6 client, DHCPv6 relay, and DHCPv6 snooping

Neighbor Discovery (ND) and ND snooping

Manual tunnel, automatic tunnel, and ISATAP tunnel for IPv6

GRE tunnel

IP routing

Static routing

RIP and RIPng

OSPFv2 and OSPFv3

GR

IPv4/IPv6 IS-IS

BGP4 and BGP4+

EVPN

IPv4/IPv6 VRF

Policy-based routing (PBR)

IPv4 and IPv6 ECMP

Multicast

IGMP v1/v2/v3

IGMP snooping v1/v2/v3

IGMP proxy

IGMP fast leave

PIM-DM, PIM-SM, and PIM-SSM

PIM-SSM for IPv4 and IPv6

MSDP to achieve inter-domain multicast

MLDv1 and MLDv2

Multicast static routing

MLD v1/v2 snooping

PIM-SMv6

Multicast source IP address check

Multicast source port check

MPLS

MPLS IPv6

MPLS L3VPN

MPLS 6VPE

MPLS MIB (RFC 1273, RFC 4265, and RFC 4382)

ACL and QoS

Standard IP ACLs (hardware ACLs based on IP addresses)

Extended IP ACLs (hardware ACLs based on IP addresses or TCP/UDP port numbers)

Extended MAC ACLs (hardware ACLs based on source MAC addresses, destination MAC addresses, and optional Ethernet type)

Expert-level ACLs (hardware ACLs based on flexible combinations of the VLAN ID, Ethernet type, MAC address, IP address, TCP/UDP port number, protocol type, and time range)

ACL80 and IPv6 ACL

Applying ACLs globally (hardware ACLs based on flexible combinations of the VLAN ID, Ethernet type, MAC address, IP address, TCP/UDP port number, protocol type, and time range)

ACL redirection

Port traffic identification

Port-based rate limiting

802.1p

Traffic classification based on 802.1p priorities, DSCP priorities, and IP precedences

CAR

Congestion management: SP, WRR, DRR, WFQ, SP+WRR, SP+DRR, and SP+WFQ

Congestion avoidance: tail drop, RED, and WRED

Eight queues on each port

Security

AAA

RADIUS authorization and accounting

TACACS+

Portal authentication, RADIUS, and TACACS+ login authentication

IEEE802.1X authentication, MAC address bypass (MAB) authentication, and interface-based and MAC address-based 802.1X authentication

Web authentication

Hypertext Transfer Protocol Secure (HTTPS)

SSHv1 and SSHv2

Global IP-MAC binding

ICMP

Port security

IP source guard

DAI

SAVI

ARP spoofing prevention

CPU Protect Policy (CPP) and NFPP

Various attack defense functions, including NFPP and ARP anti-attack

uRPF

Login authentication and password security

Unknown multicast packets are not sent to the CPU, and unknown unicast packets can be suppressed.

Reliability

Rapid Ethernet Uplink Protection (REUP)

Rapid Link Detection Protocol (RLDP), Layer 2 link connectivity detection, unidirectional link detection, and VLAN-based loop control

Data Link Detection Protocol (DLDP)

IPv4 VRRP v2/v3 and IPv6 VRRP

VRRP for the super-VLAN

BFD

RG-S7805C, RG-S7808C , RG-S7810C: 1+1 redundancy for supervisor modules

RG-S7805C: 1+1 redundancy for power supply

RG-S7808C , RG-S7810C: N+M redundancy for power supply

RG-S7805C: fan redundancy is not supported

RG-S7808C , RG-S7810C: 1+1 fan redundancy

Hot swapping of components

Hot patch and online installation of patches

GR for OSPF/IS-IS/BGP

BFD for VRRP/OSPF/BGP4/ISIS/ISISv6/static routing

Device virtualization

VSU

NMS and maintenance

SPAN, RSPAN, and ERSPAN

sFlow

NTP 

SNTP

FTP, TFTP, and Xmodem

SNMP v1/v2c/v3

RMON (1, 2, 3, 9)

NETCONF

CWMP

gRPC

OpenFlow Special 1.3

Flow table analysis defined by all protocols

Transmission of specified packets to the controller

Configuring the controller's IP address and port

Notifying port status changes to the controller

Web-based NMS

Console/Telnet/SSH2.0 CLI configuration

Fault alarms and auto-recovery

System operation logging

VXLAN

Layer 2 and Layer 3 VXLAN gateways

 

Software Specifications (with -X Series Supervisor Module)

Software Specifications

RG-S7800C-X Series

Ethernet switching 

Jumbo frame (maximum length: 9,216 bytes)

802.3az EEE

Maximum number of VLANs that can be created: 4,094

Voice VLAN

GVRP

IP subnet-based VLAN

MAC VLAN

Port-based VLAN

Private VLAN

protocol-based VLAN

Super-VLAN

Basic QinQ and selective QinQ

STP (IEEE 802.1.d)

RSTP (IEEE 802.1w)

MSTP (IEEE 802.1s)

ERPS (G.8032)

LLDP/LLDP-MED

Device Virtualization

VSU

SDN

OpenFlow 1.3

NETCONF

IP service

Static and dynamic ARP

DHCP client

DHCP relay

DHCP server

DHCP snooping

DNS

DHCPv6 client

DHCPv6 relay

DHCPv6 snooping

Neighbor Discovery (ND) and ND snooping

FTP Server

FTP Client

NTP server

NTP Client

SNTP Client

TFTP Client

TFTP Server

IP routing

Static routing

BGP4

BGP4+

IS-ISv4

IS-ISv6

OSPFv2

OSPFv3

RIP

RIPng

GR

Routing Policy

ECMP

IPv4/IPv6 VRF

Policy-based routing (PBR)

Multicast

IGMP v1/v2/v3

IGMP snooping v1/v2

IGMP proxy

IGMP fast leave

PIM-DM

PIM-SM

PIM-SSM for IPv4 and IPv6

MSDP to achieve inter-domain multicast

MLDv1 and MLDv2

Multicast static routing

MLD v1/v2 snooping

PIM-SMv6

Multicast source IP address check

Multicast source port check

MPLS

MPLS L3VPN

MPLS 6VPE

MPLS IPv6

MPLS forwarding

LDP

LSP

VXLAN

VXLAN Layer 2 bridge

VXLAN Layer 3 gateway

EVPN VXLAN

ACL and QoS

 

Standard IP ACL

extended IP ACL

extended MAC ACL

Layer 2 and Layer 3 port ACL

VLAN ACL

Expert-level ACL

ACL 80

IPv6 ACL

Applying ACLs globally

ACL COUNTER

ACL LOGGING

ACL REMARK

802.1P

SP

WRR

SP+WFR

other queue scheduling mechanisms

RED/WRED

Rate limiting based on the inbound or outbound interface

MPLS QOS

Reliability

RG-S7805C, RG-S7808C , RG-S7810C-X: 1+1 redundancy for supervisor modules

RG-S7805C: 1+1 redundancy for power supply

RG-S7808C , RG-S7810C-X: N+M redundancy for power supply

RG-S7805C: fan redundancy is not supported

RG-S7808C , RG-S7810C-X: 1+1 fan redundancy

Hot swapping of all components

Hot patching function for online patch upgrade

GR

BFD

VRRP

VRRP+

Faulty optical port isolation

Dual physical chips for boot systems

Security

NFPP

CPP

DAI

port security

IP source guard

802.1X authentication

MAC address-based authentication

Portal authentication

RADIUS

TACACS+ login authentication

uRPF

SSHv2

IPv6 SAVI

Login authentication and password security

providing encrypted security channels for user login

Unknown multicast packets are not sent to the CPU, and unknown unicast packets can be suppressed.

NMS and maintenance

Console/AUX Modem/Telnet/SSH2.0 CLI configuration

File upload and download management using FTP, TFTP, and Xmodem

SNMP V1/V2c/V3

RMON

CWMP

GRPC

Fault alarm and auto-recovery

System operation logging

sFlow

SPAN

RSPAN

ERSPAN

VLAN mirroring

Web-based NMS

Energy-Saving Design

IEEE 802.3az Energy Efficient Ethernet

 

Show More
Resources All Resources
Learn about Products or Solutions
Software and Configuration
Информация для заказа

Switch Chassis

Model

Description

RG-S7805C

RG-S7805C switch, which can accommodate three line cards and two supervisor modules (supporting -CM series and -X series supervisor modules)

RG-S7808C

RG-S7808C switch, which can accommodate six line cards and two supervisor modules (supporting -CM series and -X series supervisor modules)

RG-S7810C

RG-S7810C switch, which can accommodate eight service cards, two supervisor modules, and two switch fabric modules (supporting -CM series supervisor modules)

RG-S7810C-X

RG-S7810C-X switch, which can accommodate eight line cards, two supervisor modules, and four switch fabric modules (supporting -X series supervisor modules)

 

Supervisor Modules

Model

Description

M7805C-CM II

S7805C high-performance 2nd-generation supervisor module

M7808C-CM II

S7808C high-performance 2nd-generation supervisor module

M7810C-CM

S7810C high-performance 1st-generation supervisor module

M7810C-CM-F

S7810C high-performance 2nd-generation supervisor module

M7805C-CM-X

RG-S7805C high-performance supervisor module

M7808C-CM-X

RG-S7808C high-performance supervisor module

M7810C-CM-X

RG-S7810C-X high-performance supervisor module

Notes:

  • Different models cannot be interchanged.
  • Mandatory item, 1+1 redundancy supported, and at least one supervisor module must be configured.


Switch Fabric Modules

Model

Description

M7810C-FE-D I

RG-S7810C switch fabric module I

M7810C-FE-F I

RG-S7810C 2nd-generation switch fabric module

M7810C-FE-X I

RG-S7810C-X 1st-generation switch fabric module

M7810C-FE-X II

RG-S7810C-X 2nd-generation switch fabric module

 

Line Cards

Working with -CM series supervisor module

Model

Description

M7800C-32XS4QXS-DA

32 x 1GE/10GE SFP+ ports (LC) and 4 x 40GE QSFP+ ports (MPO), supporting splitting a 40GE port into 4 x 10GE optical ports

M7800C-24GT24SFP4XS-EB

24 x 10/100/1000BASE-T ports (RJ45), 24 x 100M/1GE SFP ports (LC) and 4 x 1GE/10GE SFP+ ports (LC)

M7800C-24SFP/12GT4XS-EB

24 x 100M/1GE SFP ports (LC), 12 x 10/100/1000BASE-T combo ports (RJ45) and 4 x 1GE/10GE SFP+ ports (LC)

M7800C-48GT4XS-EB

48 x 10/100/1000BASE-T ports (RJ45) and 4 x 1GE/10GE SFP+ ports (LC)

M7800C-48SFP4XS-EB

48 x 100M/1GE SFP ports (LC) and 4 x 1GE/10GE SFP+ ports (LC)

M7800C-48GT-FA

48 x 10/100/1000BASE-T ports (RJ45)

M7800C-48SFP-FA

48 x 100M/1GE SFP ports (LC)

M7800C-48XS-FB

48 x 1GE/10GE SFP+ ports (LC)

M7800C-8CQ-FB

8 x 40GE/100GE QSFP28 ports (LC)

Notes:

  • EB series line cards only interchanged with DA series line cards.
  • DA series line cards only interchanged with EB series line cards.
  • FA/FB series line cards cannot be interchanged with EB/DA series line cards.

 

Working with -X series supervisor module

Model

Description

M7800C-48GT4XS-XA

48 x 10/100/1000BASE-T ports (RJ45) and 4 x 1GE/10GE SFP+ ports (LC)

M7800C-48SFP4XS-XA

48 x 100M/1GE SFP ports (LC) and 4 x 1GE/10GE SFP+ ports (LC)

M7800C-24GT8SFP8XS-XA

24 x 10/100/1000BASE-T ports (RJ45), 8 x 100M/1GE SFP ports (LC) and 8 x 1GE/10GE SFP+ ports (LC)

M7800C-32XS-XA

32 x 1GE/10GE SFP+ ports (LC)

M7800C-52XS-XB

52 x 1GE/10GE SFP+ ports (LC)

M7800C-12CQ-XB

12 x 40GE/100GE QSFP28 ports (MPO/LC). One 100GE port can be split into four 25GE ports and one 40GE port can be split into four 10GE ports.

M7800C-48XT-P-XB

48 x 100/1000/2.5G/5G/10GBASE-T ports (RJ45), supporting PoE/PoE+. Each PoE port provides up to 30 W of power. The maximum power is 1440 W over 48 ports (30 W x 48).

1 x PoE in port receives PoE/PoE+ power supply. If the PoE function is used, you need to separately configure the PoE power chassis M78-PSE-X and the power module RG-PA1600I-PL for M7800C-48XT-P-XB.

M7800C-8SFG-XB

8 x SFG ports (64 x 1GE logical channels). CWDM line card for RG-S7810C-X and RG-S7808C (used with the M7808C-CM-X supervisor module)

M7800C-8SFX-XB

8 x SFX ports (64 x 10GE logical channels) with each port backward compatible with the Gigabit rate. CWDM line card for RG-S7810C-X and RG-S7808C (used with the M7808C-CM-X supervisor module)

 

Power Chassis and Modules

Model

Description

RG-PA300I-F

300 W AC power module, supporting redundancy, 10 A power cord, used with RG-S7805C

RG-PA460I-F

460 W AC power module, supporting redundancy, 10 A power cord, used with RG-S7805C

RG-PA600I

600 W AC power module, supporting redundancy, 10 A power cord, used with RG-S7810C & RG-S7810C-X

RG-PA600I-F

600 W AC power module, supporting redundancy, 10 A power cord, used with RG-S7808C

RG-PA1000I-F

1000 W AC power module, supporting redundancy, 10 A power cord, used with RG-S7805C

RG-PA1600I

1600 W AC power module, supporting redundancy, 16 A power cord, used with RG-S7810C & RG-S7810C-X

RG-PA1600I-F

1600 W AC power module, supporting redundancy, 16 A power cord, used with RG-S7808C

M78-PSE-X

PoE power chassis. 2 x PoE out ports can power two PoE line cards through specialized PoE cables. 2 x power module slots, used together with RG-PA1600I-PL (working with -X series supervisor module)

RG-PA1600I-PL

1600 W PoE AC power module, supporting redundancy, 16 A power cord, used with M78-PSE-X (working with -X series supervisor module)

RG-PD600I

600 W DC power module, supporting redundancy, 20 A power cord, used with RG-S7810C-X

 

Optical Transceivers and Cables

1GE

Model

Description

Mini-GBIC-GT

1000BASE-X to 1000BASE-T, copper SFP transceiver, RJ45, 100 m over Cat 5e/6/6a

The port needs to be configured with auto-negotiation

MINI-GBIC-SX-MM850

1000BASE-SX, SFP transceiver, 850 nm, Duplex LC, 500 m over MMF

MINI-GBIC-LX-SM1310

1000BASE-LX, SFP transceiver, 1310 nm, Duplex LC, 10 km over SMF

MINI-GBIC-LH40-SM1310

1000BASE-LH, SFP transceiver, 1310 nm, Duplex LC, 40 km over SMF

MINI-GBIC-ZX80-SM1550

1000BASE-ZX, SFP transceiver, 1550 nm, Duplex LC, 80 km over SMF

GE-SFP-LX20-SM1310-BIDI

1000BASE-LX, SFP transceiver, TX1310/RX1550, BiDi LC, 20 km over SMF

GE-SFP-LX20-SM1550-BIDI

1000BASE-LX, SFP transceiver, TX1550/RX1310, BiDi LC, 20 km over SMF

GE-SFP-LH40-SM1310-BIDI

1000BASE-LH, SFP transceiver, TX1310/RX1550, BiDi LC, 40 km over SMF

GE-SFP-LH40-SM1550-BIDI

1000BASE-LH, SFP transceiver, TX1550/RX1310, BiDi LC, 40 km over SMF

GE-SFP-LX03-SM1310-BIDI-I

1000BASE-LX, SFP transceiver, TX1310/RX1550, BiDi LC, 3 km over SMF

GE-SFP-LX03-SM1550-BIDI-I

1000BASE-LX, SFP transceiver, TX1550/RX1310, BiDi LC, 3 km over SMF

Note: BiDi transceivers must be used in pairs. If one end uses GE-SFP-LX20-SM1310-BIDI, the other end must use GE-SFP-LX20-SM1550-BIDI.


10GE

Model

Description

XG-SFP-SR-MM850

10GBASE-SR, SFP+ transceiver, 850nm, Duplex LC, 300 m over MMF

XG-SFP-LR-SM1310

10GBASE-LR, SFP+ transceiver, 1310nm, Duplex LC, 10 km over SMF

XG-SFP-ER-SM1550

10GBASE-ER, SFP+ transceiver, 1550nm, Duplex LC, 40 km over SMF

XG-SFP-ZR-SM1550

10GBASE-ZR, SFP+ transceiver, 1550nm, Duplex LC, 80 km over SMF

XG-SFP-LR10-SM1270-BIDI-I

10GBASE-LR, SFP+ transceiver, TX1270/RX1330, BiDi LC, 10 km over SMF

XG-SFP-LR10-SM1330-BIDI-I

10GBASE-LR, SFP+ transceiver, TX1330/RX1270, BiDi LC, 10 km over SMF

XG-SFP-AOC1M

10GBASE, SFP+ active optical cable (AOC), 1 m, including one cable and two optical transceivers

XG-SFP-AOC3M

10GBASE, SFP+ active optical cable (AOC), 3 m, including one cable and two optical transceivers

XG-SFP-AOC5M

10GBASE, SFP+ active optical cable (AOC), 5 m, including one cable and two optical transceivers

Note: BiDi transceivers must be used in pairs. If one end uses XG-SFP-LR10-SM1270-BIDI-I, the other end must use XG-SFP-LR10-SM1330-BIDI-I.

 

40GE

Model

Description

40G-QSFP-LSR-MM850

40GBASE-LSR, QSFP+ transceiver, 850 nm, MPO 1 x 12, 400 m over OM4 MMF, 300 m over OM3 MMF

40G-QSFP-LR4-SM1310

40GBASE-LR4, QSFP+ transceiver, 1310 nm, Duplex LC, 10 km over SMF

40G-QSFP-iLR4-SM1310

40GBASE-iLR4, QSFP+ transceiver, 1310 nm, Duplex LC, 2 km over SMF

40G-QSFP-LX4-SM1310

40GBASE-LX4, QSFP+ transceiver, 1310 nm, Duplex LC, 150 m over OM3/OM4 MMF, 2 km over SMF

40G-AOC-5M

40GBASE, QSFP+ active optical cable (AOC), 5 m, including one cable and two optical transceivers

 

100GE

Model

Description

100G-QSFP-SR-MM850

100GBASE-SR, QSFP28 transceiver, 850 nm, MPO 1 x 12, 100 m over OM4 MMF, 70 m over OM3 MMF

100G-QSFP-LR4-SM1310

100GBASE-LR4, QSFP28 transceiver, 1310 nm, Duplex LC, 10 km over SMF

100G-AOC-10M

100GBASE, QSFP28 active optical cable (AOC), 10 m, including one cable and two optical transceivers

 

CWDM Transceiver

Model

Description

SFG-LR-SM

Core switch side, 1G BASE-LR,SFG Transceiver, 8 different wavelengths (10km, LC)

SFX-LR-SM

Core switch side, 10G BASE-LR, SFP+ Transceiver, 8 different wavelengths (10km, LC)

Show More
Tips: Product information and performance will be affected by upgrade iteration, specific environment and other factors, so FAQ content is for reference only. For further information, please contact online support.
How would you rate your experience on this page?
Very disatisfying
Very satisfying
If you would like to offer more comment, please type in the textbox below, that would be helpful for the improvement of this page.
Submit
Thank you for your feedback!

Ruijie Networks websites use cookies to deliver and improve the website experience.

See our cookie policy for further details on how we use cookies and how to change your cookie settings.

Cookie Manager

When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.

  • Performance cookies

    Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.

  • Essential cookies

    This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.

Accept All

View Cookie Policy Details

Контакты

Контакты

How can we help you?

Контакты

Get an Order help

Контакты

Get a tech support

2024 Ruijie Networks Brand Awareness Survey

Your opinions and feelings are crucial for our improvement.

Fill in the survey